Files
start-os/web
Aiden McClelland cfbace1d91 fix: add CONNMARK restore-mark to mangle OUTPUT chain
The CONNMARK --restore-mark rule was only in PREROUTING, which handles
forwarded packets. Locally-bound listeners (e.g. vhost) generate replies
through the OUTPUT chain, where the fwmark was never restored. This
caused response packets to route via the default table instead of back
through the originating interface.
2026-02-16 19:22:07 -07:00
..
2023-11-13 15:59:16 -07:00
2023-11-13 15:59:16 -07:00
2025-04-13 13:03:51 -06:00
2026-01-27 14:44:41 -08:00
2023-11-13 15:59:16 -07:00
2026-02-14 08:15:50 -07:00
2025-12-31 11:30:57 -07:00
2025-07-18 18:31:12 +00:00
2026-02-14 08:15:50 -07:00
2025-07-18 18:31:12 +00:00
2023-11-13 15:59:16 -07:00
2025-04-17 09:00:59 -06:00

StartOS Web

Angular + TypeScript workspace using the Taiga UI component library.

Applications

StartOS serves one of these UIs depending on the state of the system:

  • ui — Primary admin interface for managing StartOS, served on hosts unique to the instance.
  • setup-wizard — Initial setup UI, served on start.local.
  • start-tunnel — VPN/tunnel management UI.

Libraries

  • shared — Common code shared between all web UIs (API clients, components, i18n).
  • marketplace — Library code for service discovery, shared between the StartOS UI and the marketplace.

Contributing

See CONTRIBUTING.md for environment setup, development server instructions, and translation guides.